Main field of application
Cleaning of heat exchangers, DeNOx, air preheaters  and gas-gas heaters  with steam, air or high pressure water at flue gas temperatures < 800 °C.
Travel
Principle of cleaning
 


 

  • The blowing and the scavenging tube are installed in the gas or air heater and are axially shiftable mounted – the blowing element remains in the flue gas pass.
  • During the blowing process the blowing and the scavenging tube continue to move further into the heater.
  • On reaching the front-side end position the direction of movement changes and the lance tube returns to its starting position.

 
Special features

  • integrated stop valve with adjustable throttle disc for comfortable adjustment of the blowing pressure
  • temperature-resistant blowing rake material
  • high-performance nozzles
  • stainless feed tube material
  • travel monitoring by limit switch
  • integrated gear motor for advance movement